Phakic Family - Intraocular lens
manufacturer in
India

Phakic Family-Intraocular lens manufacturer in India
Phakic Family-Intraocular lens manufacturer in India

Material – Hydrophilic Acrylic, CI 26, Clear, UV Protection
Optic Type – Aspheric
Overall Length – 11.00 to 14.00 mm
Overall Diameter – 4.25 to 6.00 mm
Dioptre Range – -1.0 D to -23.0D (with 0.5D step increment)
Cylinder Range – 0.5D to 5.0D (with 0.5D step increment)
Refractive Index – 1.465
Implantation Site – Posterior Chamber
Sterilization – Steam

Model – APL 20
Size(mm) – 12.00 mm

Model – APL 25
Size(mm) – 12.50 mm

Model – APL 30
Size(mm) – 13.00 mm

Model – APL 35
Size(mm) – 13.50 mm

Model – APL 40
Size(mm) – 14.00 mm

Phakic Family-Intraocular lens manufacturer in India

Phakic Family- Advanced Adtec Phakic IOL Technology for High Myopia Correction

Introduction 

The Adtec Phakic Lens (APL) is a precisely engineered intraocular medical device
designed to provide internal correction of refractive errors. By compensating for the eye’s
optical aberrations within the anterior chamber, the APL minimizes or eliminates the patient’s
dependence on external refractive aids such as spectacles or contact lenses.
This intraocular solution offers enhanced visual acuity, stable refractive outcomes, and
preservation of corneal integrity, thereby improving the patient’s overall visual
performance and quality of life.

Central Flow Design

The APL incorporates an optically centred micro-hole that facilitates physiological
aqueous humour circulation from the posterior to the anterior chamber. This feature
negates the requirement for a peripheral iridectomy by enabling a direct and controlled
pathway for fluid movement, thereby maintaining stable intraocular pressure and reducing
postoperative complications.

Key Design Attributes of the Central Flow System:

  1. Centralized aperture for uniform aqueous exchange
  2.  Radially symmetric structure ensuring optical and mechanical stability
  3.  Hierarchical flow architecture promoting smooth intraocular dynamics
  4.  Single-point aqueous communication minimizing turbulence and stagnation
Phakic Family-Intraocular lens manufacturer in India
Phakic Family-Intraocular lens

Clinical Benefits of the Adtec Phakic Lens Family

  • Provides effective correction for high myopia, beyond the range treatable by
    corneal refractive procedures
  • Preserves the eye’s natural accommodative function, unlike lens-exchange techniques
  • Suitable for patients contraindicated for LASIK or PRK due to corneal thickness or irregularity
  • Demonstrates excellent refractive predictability and long-term biocompatibility

Radial Profile and Vaulted Design

The Adtec APL is designed with a vaulted radial profile to maintain a defined clearance between the posterior surface of the phakic IOL and the anterior surface of the crystalline lens. This configuration ensures no direct contact with either the posterior iris or crystalline lens, allowing unimpeded aqueous circulation. The optimized vaulting and edge contouring help prevent pigmentary dispersion, cataract genesis, and other late-onset complications, ensuring long-term ocular safety and stability.

Phakic Family-Intraocular lens manufacturer in India

Material – Hydrophilic Acrylic, CI 26, Clear, UV Protection
Optic Type – Aspheric
Overall Length – 11.00 to 14.00 mm
Overall Diameter – 4.25 to 6.00 mm
Dioptre Range – -1.0 D to -23.0D (with 0.5D step increment)
Cylinder Range – 0.5D to 5.0D (with 0.5D step increment)
Refractive Index – 1.465
Implantation Site – Posterior Chamber
Sterilization – Steam

Model – APL 20T
Size(mm) – 12.00 mm

Model – APL 25T
Size(mm) – 12.50 mm

Model – APL 30T
Size(mm) – 13.00 mm

Model – APL 35T
Size(mm) – 13.50 mm

Model – APL 40T
Size(mm) – 14.00 mm

Phakic Family-Intraocular lens manufacturer in India

Adtec APL Toric IOLs

The Adtec APL Toric reduced preoperative spherical and astigmatic errors with high predictability and good stability and was associated with extremely good visual outcomes and patient satisfaction. The use of Adtec APL Toric has advantages over Corneal procedures. Adtec APL Toric has excellent predictability and stability for the correction of moderate to high myopic astigmatism. Adtec APL Toric is an effective means for improving visual functional quality of life in highly ametropic children who have difficulties wearing spectacles
Phakic Family-Intraocular lens
Phakic Family-Intraocular lens manufacturer in India

APL Materials

Hybrid Version (A)
The Adtec APL Hybrid is manufactured from a high-performance, biocompatible polymer that ensures exceptional optical clarity and mechanical stability. Its soft, flexible structure allows for smooth implantation and excellent postoperative adaptation, providing a natural feel within the eye and minimizing mechanical interaction with ocular tissues.

Version (B)

This version utilizes a collagen-containing copolymer, combining polymer strength with the biocompatibility of natural collagen. The single-piece, soft, elastic, and hydrophilic design ensures ease of implantation and
long-term ocular harmony. The collagen component enhances cellular compatibility, reducing postoperative
inflammation and ensuring stable optical performance over time.

General Features

Zero aberration, polish free, Lathes Cut, lens surface

Adtec Intraocular Lenses are manufactured using Sterling Nanoform X, one of the world’s most advanced ultra-precision CNC lathe systems, capable of achieving cutting accuracy up to 0.0001 microns. This state-of-the-art technology ensures a polish-free, aberration-free surface, delivering exceptional optical precision. The result is blur-free, high-definition image quality with enhanced contrast sensitivity and superior visual resolution — providing surgeons and patients with uncompromised optical performance.

Phakic Family-Intraocular lens manufacturer in India
Phakic Family-Intraocular lens manufacturer in India

Glistening free IOLs- Optimally Pre-hydrated

Adtec IOLs are engineered to be glistening-free through an optimized pre-hydration process that achieves equilibrium water content prior to implantation. This stabilization protects the lens material against temperature and environmental variations, ensuring consistent optical clarity over time. As glistening density increases, light scattering intensifies and Modulation Transfer
Function (MTF) performance declines. Adtec’s proprietary hydration technology effectively eliminates this risk — with laboratory evaluations (using Miyake scales) consistently showing
zero mean glistening values, confirming the lens’s exceptional resistance to microvacuole formation and long-term optical stability.

Adaptive Ocular Sciences Pvt. Ltd.    is one of the fastest-growing innovators in intraocular lens manufacturing. We provide a comprehensive range of advanced IOLs for refractive cataract surgery, integrating innovative optical design and engineering to deliver exceptional visual quality and patient outcomes.