Material – Hydrophilic Acrylic, CI 26, Clear, UV Protection
Optic Type – Aspheric
Overall Length – 11.00 to 14.00 mm
Overall Diameter – 4.25 to 6.00 mm
Dioptre Range – -1.0 D to -23.0D (with 0.5D step increment)
Cylinder Range – 0.5D to 5.0D (with 0.5D step increment)
Refractive Index – 1.465
Implantation Site – Posterior Chamber
Sterilization – Steam
Model – APL 20
Size(mm) – 12.00 mm
Model – APL 25
Size(mm) – 12.50 mm
Model – APL 30
Size(mm) – 13.00 mm
Model – APL 35
Size(mm) – 13.50 mm
Model – APL 40
Size(mm) – 14.00 mm
The APL is a specialized medical device designed to provide internal compensation for the dysfunctional refractive condition of the eye. By addressing these refractive issues directly within the eye, the APL helps to reduce or eliminate a patient’s dependence on external visual aids such as glasses or contact lenses. This innovative solution enhances visual clarity and improves overall quality of life for individuals with refractive errors, offering a convenient and effective alternative to traditional corrective methods.
Material – Hydrophilic Acrylic, CI 26, Clear, UV Protection
Optic Type – Aspheric
Overall Length – 11.00 to 14.00 mm
Overall Diameter – 4.25 to 6.00 mm
Dioptre Range – -1.0 D to -23.0D (with 0.5D step increment)
Cylinder Range – 0.5D to 5.0D (with 0.5D step increment)
Refractive Index – 1.465
Implantation Site – Posterior Chamber
Sterilization – Steam
Model – APL 20
Size(mm) – 12.00 mm
Model – APL 25
Size(mm) – 12.50 mm
Model – APL 30
Size(mm) – 13.00 mm
Model – APL 35
Size(mm) – 13.50 mm
Model – APL 40
Size(mm) – 14.00 mm
The APL is a specialized medical device designed to provide internal compensation for the dysfunctional refractive condition of the eye. By addressing these refractive issues directly within the eye, the APL helps to reduce or eliminate a patient’s dependence on external visual aids such as glasses or contact lenses. This innovative solution enhances visual clarity and improves overall quality of life for individuals with refractive errors, offering a convenient and effective alternative to traditional corrective methods.
A central hole promotes more physiological aqueous circulation from the pupil to the anterior chamber, effectively eliminating the need for a peripheral iridectomy by providing a direct pathway for fluid movement and reducing intraocular pressure complications.
The Adtec APL is designed to create space between the posterior chamber phakic IOL and the anterior surface of the crystalline lens, preventing contact while allowing fluid flow. Its vaulted design ensures no contact with the posterior iris or crystalline lens, reducing the risk of late complications such as pigmentary dispersion syndrome and complicated cataracts.